Autonics / MODEL

PRCM08-2DP

PR DC 3-wire Cylindrical Inductive Proximity Sensors

Autonics PRCM08-2DP — Detection Mode: Inductive; Sensing Distance: 2 mm; Housing / Thread Size: M8.

Detection Mode
Inductive
Sensing Distance
2 mm
Housing / Thread Size
M8
Output Type
PNP

Overview

Autonics PRCM08-2DP: 2 mm inductive sensing, M8, non-flush installation, PNP normally open (no) output and m12 connector connection. General type. Specifications are based on the supplied PR DC 3-wire manual (PDF p. 2); the exact ordering code is listed on PDF p. 6.

Specifications

Detection ModeInductivePR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Metal-target sensing.
Sensing Distance2 mmPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Standard iron target 8 × 8 × 1 mm.
Housing / Thread SizeM8PR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Thread pitch: M8 × 1.
Output TypePNPPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. DC 3-wire transistor output.
Operation ModeNormally open (NO)PR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Output timing defined by target presence.
Mounting TypeNon-flushPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Refer to mounting clearances in manual p. 3.
Wiring SystemDC 3-wirePR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Connection TypeM12 connectorPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Connector SizeM12PR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Connector cable is sold separately for connector models.
Supply Voltage12-24 VDCPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Operating voltage: 10-30 VDC; ripple (p-p) ≤10%.
Current Consumption≤10 mAPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Maximum Output Current / Derating≤200 mAPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Residual Voltage≤2.0 VPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Response Frequency1.0 kHzPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Average value using the standard target; target width set to twice the standard target size and target distance to half the rated sensing distance.
Operating Temperature-25 to +70 °CPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. No freezing or condensation.
Storage Temperature-30 to +80 °CPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. No freezing or condensation.
Operating Humidity35-95 %RHPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Operating and storage; no freezing or condensation.
IP RatingIP67PR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. IEC protection structure; not a claim of model-specific certification.
Housing MaterialSUS303 stainless steelPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. SUS303 applies to the Ø8 mm connector-type case.
Sensing Surface MaterialPBTPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Hysteresis≤15% of sensing distancePR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
CharacteristicGeneralPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Body Length VariantNormalPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Setting Distance0-1.4 mmPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Use within 70% of nominal sensing distance for stable sensing; manual p. 3.
Standard Sensing TargetIron, 8 × 8 × 1 mmPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Temperature Influence≤±20% of sensing distancePR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Relative to sensing distance at +20 °C.
Protection CircuitsSurge protection; output short-circuit overcurrent protection; reverse-polarity protectionPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Operation IndicatorRed operation indicatorPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6.
Insulation Resistance≥50 MΩPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Measured with a 500 VDC megohmmeter.
Dielectric Strength1,500 VAC, 50/60 Hz, 1 minPR DC 3-wire product manual, PDF p. 2; exact code and dimensions: p. 6. Between live parts and case.

Document

PDFautonics-pr-dc-3-wire-manual-en.pdfPR Series DC 3-wire Product Manual (English) · Shared series document

Request this model

Send the exact ordering code, quantity or product list.

Request a Quote
WhatsApp

Request a Quote

Fields marked * are required.

PDF, XLS, XLSX, CSV, DOC, DOCX, JPG or PNG
Up to 5 files · 10 MB each · 50 MB totalDo not include sensitive personal information or documents you are not permitted to share.

A confirmation page appears only after your inquiry is recorded. For email correspondence, contact sales@brolenz.com.