SICK / MODEL

RLY3-HAND100

RLY3 ReLy Safety Relays

SICK RLY3-HAND100 — Application: Evaluation unit; SICK Part Number: 1085346; Safety Contact Configuration: 2 instantaneous N/O.

Application
Evaluation unit
SICK Part Number
1085346
Safety Contact Configuration
2 instantaneous N/O
Power Supply Type
PELV or SELV

Overview

Use the exact ordering code and the applicable operating instructions. Catalogue ratings describe the module, not the validated safety level of a complete machine. Current availability has not been checked.

Specifications

ApplicationEvaluation unit
SICK Part Number1085346
Safety Contact Configuration2 instantaneous N/OImmediate and release-delayed safety paths are distinguished; non-safe feedback, signaling and diagnostic outputs are not included here.
Power Supply TypePELV or SELV
Compatible Sensor TypesTwo-hand controls Type III C, in accordance with EN 574 (as referenced by this catalogue)
Instantaneous Safety Paths (N/O)2
Nominal Housing Width18 mmNominal housing width. Front-connector envelope and installation dimensions are shown separately in the p.14 drawings.
Connection Typefront connector with spring terminals
Catalogue Safety Integrity LevelSIL3 (IEC 61508) SILCL3 (IEC 62061)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine.
Catalogue Safety CategoryCategory 4 (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine.
Catalogue Performance LevelPL e (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine.
Mission Time20 years (ISO 13849-1)Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine.
PFHd (Mean Dangerous Failure Probability per Hour)1.0 x 10^-9 /hCatalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine.
Stop Category (IEC 60204-1)0Catalogue-stated rating (8021876/2021-10-22). Achievable application safety depends on the circuit, wiring and applicable operating instructions; this is not a certification of the complete machine.
Listed Monitoring FunctionsExternal device monitoring (EDM)
Safety Inputs4For connecting 2 control devices, each with normally closed and normally open contacts (p.8 footnote 1).
Dedicated EDM Inputs1
Display ElementsLEDs
Supply Voltage Vs24 V DC (16.8 V to 30 V)
Residual Ripple≤ 2.4 V
Power Consumption≤ 2.5 W (DC)
Safety Input Voltage HIGH24 V DC (11 V to 30 V)
Safety Input Voltage LOW0 V DC (-3 V to 5 V)
Safety Input Current4 mA to 6 mA
Actuator Synchronization Time≤ 500 ms
Configuration MethodHard wired
Dedicated EDM Voltage HIGH24 V DC (11 V to 30 V)
Dedicated EDM Voltage LOW0 V DC (-3 V to 5 V)
Dedicated EDM Input Current4 mA to 6 mA
Instantaneous Safety Path Response Time10 ms
Instantaneous Safety Contact TypeN/O contacts, positively guided
Safety Contact MaterialSilver alloy, gold flashed
Instantaneous Safety Path Switching Voltage10 V AC to 230 V AC 10 V DC to 230 V DC
Instantaneous Safety Path Switching Current10 mA to 6 A
Maximum Total Safety Path Current12 AMaximum total current across the enabling paths; observe the operating instructions.
Mechanical Life (Switching Cycles)10^7 cycles
Overvoltage CategoryIII (EN 60664-1)
Rated Impulse Withstand Voltage6 kV (EN 60664-1)
Application Diagnostic Outputs (Not Safe): Count1
Application Diagnostic Outputs (Not Safe): TypePush-pull semiconductor output, short-circuit protected
Application Diagnostic Outputs (Not Safe): Voltage HIGH≥ Vs - 3 V
Application Diagnostic Outputs (Not Safe): Voltage LOW≤ 3 V
Application Diagnostic Outputs (Not Safe): Input Current (NPN)≤ 15 mA
Application Diagnostic Outputs (Not Safe): Output Current (PNP)≤ 120 mA
Weight130 g
Enclosure RatingIP20 (IEC 60529)
Ambient Operating Temperature-25 to +55 °C
Storage Temperature-25 to +70 °C
Air Humidity10 to 95%, non-condensing
Interference EmissionAccording to IEC 61000-6-4Standard identifiers and values are quoted from the 2021 catalogue; no current certificate or complete-system compliance is inferred.
Interference ResistanceAccording to IEC 61326-3-1; IEC 61000-6-2; IEC 60947-5-1Standard identifiers and values are quoted from the 2021 catalogue; no current certificate or complete-system compliance is inferred.

Document

PDFsick-rly3-safety-relays-en.pdfSICK ReLy RLY3 Safety Relays - English Product Information (8021876/2021-10-22) · Shared series document

Request this model

Send the exact ordering code, quantity or product list.

Request a Quote
WhatsApp

Request a Quote

Fields marked * are required.

PDF, XLS, XLSX, CSV, DOC, DOCX, JPG or PNG
Up to 5 files · 10 MB each · 50 MB totalDo not include sensitive personal information or documents you are not permitted to share.

A confirmation page appears only after your inquiry is recorded. For email correspondence, contact sales@brolenz.com.